이벤트 배너

전체 카테고리

추천 메뉴

공지사항


MCC USB-CTR08

공유
SNS 공유하기
  • 페이스북 공유
    페이스북
  • 트위터 공유
    트위터
  • 핀터레스트 공유
    핀터레스트
  • 카카오톡 공유
    카카오톡링크
  • 카카오스토리 공유
    카카오스토리
  • 짧은설명
    High-speed counter/timer device with eight counter I/O / 6069-410-028
  • 판매가
    765,600 <관세ㆍ부가세포함>
  • 구매제한
    최소 1개
  • 구매혜택

    할인 :

    적립 마일리지 :

  • 배송비
    0원 조건별배송
    금액별배송비
    0원 이상 ~ 66,000원 미만 2,700원
    66,000원 이상 0원

    배송비 계산 기준 : 판매가 + 옵션가 + 추가상품가 + 텍스트옵션가 - 상품할인가 - 상품쿠폰할인가

    택배  /  주문시결제(선결제)
    방문 수령지 : 경기도 성남시 중원구 사기막골로 99 성남센트럴비즈타워2차 B동 913호
  • 상품코드
    1000618678
  • 제조사
    Digilent
MCC USB-CTR08
0
  • 총 상품금액
  • 총 할인금액
  • 총 합계금액

상품상세정보

▶ Product Subtitle

High-speed, 8 channel, counter/timer device with 8 digital I/O

▶ Product Description

The Measurement Computing USB-CTR08 is a USB-based, high-speed counter/timer device and features 8 counter inputs, 48 MHz input frequency, up to 64-bit resolution, up to 8 MB/s scan rates, multiple counter modes, four pulse-width modulation (PWM) timers, and eight digital I/O. This device is USB-powered and requires no external power.

The USB-CTR08 device provides high-speed counter/timer operations synchronized with digital I/O functions. The eight-channel USB-CTR08 features high frequency and scan rates, debounce filtering, support for multiple counting modes, and software-selectable resolution up to 64 bits. The device also provides eight individually-configurable digital I/O channels.

USB-CTR08 supports an aggregate throughput rate of 8 MB/s. The device can be configured for any resolution up to 64-bits, eliminating the need to cascade counters. The following data streaming rates for these common resolution settings are supported; 16-bit: 4 MS/s, 32-bit: 2 MS/s, 64-bit: 1 MS/s. Each counter channel has a connection point for counter input, counter output, and counter gate.

Counter inputs can be read asynchronously under program control, or synchronously with digital inputs as part of a digital scan group. In both cases, counters can be configured to function in one of the following ways; counter resets to 0 after each read, counter counts up or down and then rolls over at a user-set limit, and counter counts until the user-set limit has been reached. Counter inputs can concurrently monitor time periods, frequencies, pulses, and other event-driven incremental occurrences directly from pulse-generators, limit switches, proximity switches, and magnetic pick-ups.

Counter gates use input signals to clear a counter, change counter direction, or start/stop counting. Gate options are software-selectable.

Counter outputs can be used to control or transmit signals to external devices, and also to counter inputs, counter gates, or digital inputs.

The USB-CTR08 supports the following counter input modes; totalize mode (event counter), period measurement mode, pulse-width measurement mode, and timing measurement mode. Counter input modes are software-selectable. Some modes include the max limit and the min limit register values, which do not directly affect the current count, but set limits in some modes to determine counter behavior.

In period measurement mode, the device measures the period of any signal at a counter input (CxIN). The device counts the integral number of ticks that make up the period, and the data returned is always time measured in ticks. The measurement period is the time from edge-to-edge, either both rising or both falling. Period data is latched as it becomes available and is acquired at the counter read rate. The data returned is interpreted as time measured in ticks. This data represents the number of tick size intervals counted during the period measurement.

In pulse width measurement mode, the device measures the time from the rising edge to the falling edge, or vice versa, on a counter input signal (CxIN). The measurement is either pulse width low or pulse width high, depending upon the edge detection setting. Every time the pulse width measurement is latched from the counter, the counter is immediately cleared and enabled to count the time for the next pulse width. The pulse width measurements are latched as they become available. The data returned is interpreted as time measured in ticks. This data represents the number of tick size intervals counted during the pulse width measurement.

In timing mode, the device measures the time between an event on the counter input (CxIN) and a subsequent event on the counter gate (CxGT), such as the rising or falling edge of one event with respect to the rising or falling edge of another event (based on the edge detection setting).

The USB-CTR08 has debounce circuitry which eliminates switch-induced transients that are typically associated with electromechanical devices including relays, proximity switches, and encoders. All debounce filter options are software selectable. You can select a debounce time, debounce mode, and rising-edge or falling-edge sensitivity. Each channel can be debounced with 16 programmable debounce times in the range of 500 ns to 25.5 ms. The signal from the buffer can be inverted before it enters the debounce circuitry. The inverter is used to make the input rising edge or falling-edge sensitive.

The USB-CTR08 has eight digital I/O lines. The digital I/O connectors can detect the state of any TTL-level input.

The USB-CTR08 includes four 32-bit timer outputs. Each timer can generate a programmable width pulse with a software selectable frequency in the range of 0.02235 Hz to 48 MHz. At higher frequencies, the timer output frequency and duty cycle depend on the load impedance and the supply. The timer output rate and pulse width can be updated asynchronously at any time; however, doing so results in a pulse stream that is not seamless.

Users can pace synchronous acquisition of counter data by the onboard clock or by an external clock connected to the external clock input connector.

Software support includes DAQami, an out-of-the-box application for data logging, visualization, and signal generation. Data can be viewed in real-time or post-acquisition on user-configurable displays. Drivers are included for the most popular applications and programming languages including Visual C++®, Visual C#®, Visual Basic®.NET, DASYLab®, LabVIEW™, and Python™.

 

▶ Features

  • 8 counter inputs
  • 48 MHz maximum input frequency
  • Software-selectable resolution up to 64-bits
  • Aggregate scan rate of 8 MB/s
  • Supports Totalize, Period, Pulsewidth, and Timing counter input modes
  • Four independent pulse-width modulation (PWM) timers
  • Eight bit-configurable digital I/O channels
  • Synchronous high-speed reads of digital and counter inputs
  • Includes
    • USB cable

▶ Support Materials

▶ Demo / Project Links

·         MCC Software Overview

·         MCC Software Downloads

·         MCC example programs 

·         USB-CTR08 Manual  

▶ What's Included

  • USB-CTR08
  • USB cable
  • Printed insert: DAQami Quick Start
  • MCC packaging assembly/foam, etc.

배송안내

 국내재고가 있는 경우 결제일로부터 3일 안에 발송됩니다.

 국내재고가 없는 경우 결제일로부터 3주 안에 발송됩니다.

 제조사 재고가 부족하여 3주 안에 배송이 어려울 경우 메일로 안내해 드리니 참고하시기 바랍니다.

교환 및 반품안내

 제품 수령후 7일이내에 이니프로 고객센터에 연락하여 교환 및 반품 처리 요청하면 교환 가능합니다.

 제품 및 제품포장 박스 등에 손상된 부분이 없어야 하며 고객센터에서 확인 후 교환 및 반품 처리됩니다.

환불안내

 제품 수령후 7일이내에 이니프로 고객센터에 연락하여 취소 및 환불 처리 요청하면 환불 가능합니다.

 제품 및 제품포장 박스 등에 손상된 부분이 없어야 하며 고객센터에서 확인 후 취소 및 환불 처리됩니다.

AS안내

 제조사 정책상 A/S가 되지 않는 제품입니다.

 납품후 30일 이내 초기제품불량인 경우에만 새제품으로 교체해 드립니다.

이미지 확대보기

MCC USB-CTR08

MCC USB-CTR08
MCC USB-CTR08
MCC USB-CTR08
MCC USB-CTR08
MCC USB-CTR08

비밀번호 인증

글 작성시 설정한 비밀번호를 입력해 주세요.

확인

장바구니 담기

상품이 장바구니에 담겼습니다.
바로 확인하시겠습니까?

이벤트 배너
최근본상품
0/0
상단으로 이동